YY210 Protective Clothing Contact Heat Transmission Test Machine

HK$0.00

Description:

The instrument use the heating cylinder to provide a constant temperature in contact with the sample under certain load and a calorimeter to measure the heat transfer properties; the instrument is easy to operate.the data is accurate, safe and reliable, widely used in fire protective clothing related companies and inspection departments.

Test standard:

ISO 12712-1

Technical Parameters

1.     The device is consists of a control box and stainless steel test gantry;

2.     The sample holder is automatic lifting, the lifting speed is 5mm ± 0.2mm / s

3. Thek type sheathed thermocouples, diameter 2mm, temperature measurement accuracy of 0.1 °C;

4.     The heating barrel temperature is greater than 500 C; the contact surface of the sample diameter 25.2 +0.05mm

5.     The barrel heating load weight 49N, can be adjusted;

6. Timer scope 99999s; timing accuracy 0.1s;

7.     Calorimeter fixed disk diameter 25mm, thickness 5mm; and assembly platinum resistance temperaturesensor;

8.     Support frame material is nylon 66; diameter 40mm height 50mm;9.Specimen diameter 80mm;

10. PLC and touch screen for intelligent control system;

11. PiD intelligent temperature control, the system automatically collect temperature data;12. The system automatically calculates test data, automatic storage; can print freely;13. The test table size: 650mm x 350 mm x 650mm;

14.Power supply 220V 50 /60Hz, power 800w.

Description:

The instrument use the heating cylinder to provide a constant temperature in contact with the sample under certain load and a calorimeter to measure the heat transfer properties; the instrument is easy to operate.the data is accurate, safe and reliable, widely used in fire protective clothing related companies and inspection departments.

Test standard:

ISO 12712-1

Technical Parameters

1.     The device is consists of a control box and stainless steel test gantry;

2.     The sample holder is automatic lifting, the lifting speed is 5mm ± 0.2mm / s

3. Thek type sheathed thermocouples, diameter 2mm, temperature measurement accuracy of 0.1 °C;

4.     The heating barrel temperature is greater than 500 C; the contact surface of the sample diameter 25.2 +0.05mm

5.     The barrel heating load weight 49N, can be adjusted;

6. Timer scope 99999s; timing accuracy 0.1s;

7.     Calorimeter fixed disk diameter 25mm, thickness 5mm; and assembly platinum resistance temperaturesensor;

8.     Support frame material is nylon 66; diameter 40mm height 50mm;9.Specimen diameter 80mm;

10. PLC and touch screen for intelligent control system;

11. PiD intelligent temperature control, the system automatically collect temperature data;12. The system automatically calculates test data, automatic storage; can print freely;13. The test table size: 650mm x 350 mm x 650mm;

14.Power supply 220V 50 /60Hz, power 800w.